Water Levels

Q. I think Iā€™m losing water.

A. First put a mark on the side of the skimmer faceplate with pencil or tape. Monitor this mark for a 24-hour period. If water drops by more than an inch, shut the system down for a 12 hour period and monitor to see if water drops faster with the pump on or off. If water drops faster with the system on, the probability of an underground plumbing leak is good. If water drops at the same rate with the system on or off, the probability of a liner leak exists.
Note: High wind areas, non-use of a solar blanket and backwashing are all things to consider.